Rheem Power Tripping: Replacing Isolator for Rheem Storage Water Heater at Verdale on 3 Feb 2025

A homeowner at Verdale faced a serious Rheem Power Tripping issue. Each time the water heater switch was turned on, the MCB tripped, leaving them without hot water. They reached out to Homeone for help. Our team responded swiftly to diagnose and resolve this Rheem Power Tripping fault.

Through detailed inspection, we uncovered unsafe electrical work that posed fire risks. Here’s how we fixed the Rheem Power Tripping issue safely and professionally.

  • Project location

    Verdale

  • Property type

    Condominium

Rheem Power Tripping.Condo. 00

Before

This image shows a severe Rheem power trip issue at a verdale. The isolator cable was found burnt, and a non-compliance cable was used, leading to safety risks. The MCB tripped every time the Rheem heater was switched on. This dangerous setup required urgent rewiring and isolator replacement to prevent fire hazards.

After

Replacing the new isolator, we resolved the Rheem power tripping issue by installing a compliant and fire-rated 2.5mm cable. The upgraded isolator setup ensures safer power delivery to the Rheem 40L water heater, eliminating risks caused by previous non-compliant wiring. System now fully tested and restored.

Rheem Power Tripping: Replacing Isolator for Rheem Storage Water Heater at Verdale

Site Findings:

Upon arriving at the Verdale residence, our technician immediately began investigating the Rheem Power Tripping complaint. The customer described that the power tripping happened the moment the heater switch was turned on. This indicated a likely fault between the heater and its isolator or main circuit.

Upon opening the isolator, we found a burnt wire inside. There were visible signs of moisture within the isolator, which had caused the internal wiring to short. More critically, the cable that connected the Rheem storage water heater to the isolator switch was not up to electrical specification — the insulation was thin, and the core material was degrading.

This dangerous combination of water ingress and substandard wiring was the root cause of the Rheem Power Tripping. Moisture inside the isolator caused a short circuit, and the non-compliant cable amplified the risk by overheating and burning.

Proposed Solution:

To resolve the Rheem Power Tripping problem and prevent future occurrences, Homeone proposed the following:

  1. Immediate replacement of the faulty isolator with a new weatherproof model.

  2. Replacement of the existing cable from the isolator to the Rheem heater with a proper 2.5mm² cable, as per PUB safety standards.

  3. Full electrical testing of the heater circuit after repairs.

These steps ensure the Rheem Power Tripping issue is not only resolved but also prevents similar risks in future.

Job Scope:

1. Testing & Fault Identification:

  • Conduct initial testing of the MCB and heater circuit.

  • Confirm tripping upon heater switch activation.

  • Inspect isolator and verify moisture and burnt cable issue.

2. Electrical Replacement Work:

  • Remove the faulty isolator switch.

  • Replace with a new weatherproof isolator.

  • Remove old, substandard wiring from the heater to the isolator.

  • Install new 2.5mm² fire-rated electrical cable with proper insulation and labeling.

3. Final Testing & Verification:

  • Test continuity and insulation resistance of new wiring.

  • Power on the heater to verify no more Rheem Power Tripping.

  • Monitor MCB performance post-repair.

4. Workplace Tidying:

  • Clean up all debris and old parts.

  • Ensure no tools, cable off-cuts or packaging left on-site.

5. Documentation & Payment:

  • Obtain customer signature on job completion form.

  • Provide digital receipt and repair summary.

  • Process payment securely.

  • Explain transfer terms & conditions: 30-day workmanship warranty, non-transferable, parts covered only if supplied by Homeone.

Conclusion:

The Rheem Power Tripping incident at Verdale was more than just a nuisance—it was a serious electrical hazard. Moisture inside the isolator and the use of a non-compliant cable created the perfect conditions for electrical fires or electric shocks. Thankfully, the homeowner acted fast by contacting Homeone.

Our prompt response, professional diagnosis, and full compliance repair work not only resolved the Rheem Power Tripping but also made the system safer than before. By replacing the isolator and upgrading the cable to the right specifications, we ensured the household can now use hot water safely and confidently.

If you’re facing Rheem Power Tripping or similar electrical faults, contact Homeone — your safety is our top priority.

 

For any water heater concerns, trust Homeone to deliver safe, efficient, and fully compliant solutions.

Condo Name:  Verdale

Read More About Us

Homeone Home Page
Shop
Portfolio
Services
Blogs
About Us
Contact Us

Our Water Heater Services

#Storage Water Heater
#Rheem
#Joven
#Ariston
#Gas Heater
#Paloma
#Ferroli
#Rinnai
#Electrical
#Aircon Services

Follow our Social Media

#FaceBook
#YouTube

Got A Question?

Feel free to reach out to us, if you have any enquiries

Log Out

Are you sure want to log out?
preloader