10 Jul 2026

SkyPark Residences

Gas Water Heater Powerd by Citygas Replacement at SkyPark Residences

  • Project location

    SkyPark Residences

  • Property type

    Condominium

CO leak Gas Water Heater power by Citygas at Skypark - Before & After

24 Feb 2026

Gas Heater Powered by Citygas Replacement at Skypark Residences

📍 SkyPark Residences at Sembawang Drive

A homeowner at SkyPark Residences in Sembawang contacted Homeone when their gas water heater stopped performing reliably. The condo received its Temporary Occupation Permit in 2016, which meant the original heater had been in service for close to a decade — right at the end of a gas water heater’s typical lifespan.

Rather than quoting a replacement over the phone, we started the way we always do: with a site assessment, so we knew exactly what condition the existing heater was in before recommending anything.

🏢 condo 🔥 Gas Heater ✅ Compliant with Gas Supply Regulations
CO leak Gas Water Heater power by Citygas at Skypark - Before & After

Old gas heater:

Gas Heater Power by Citygas

New gas heater:

Macro Gas Heater – MA-20WODP

CO leak Gas Water Heater power by Citygas at Skypak Before 1

What the Site Assessment Found

The inspection confirmed the heater was beyond economical repair:

  • Internal water leakage on the pipes and heat exchanger — damage that cannot be reliably repaired on a unit this age.
  • A corroded heat exchanger shedding copper corrosion dust onto the burner below.
  • A corroded, obstructed burner. When the burner cannot combust cleanly, the gas does not burn completely — and incomplete combustion produces carbon monoxide (CO).

We then carried out a CO leak test. The reading exceeded the widely referenced 50 PPM occupational exposure threshold — a clear fail.

Why We Shut the Gas Valve Immediately

Carbon monoxide is called the silent killer for a reason: it is invisible, odourless and tasteless. You cannot see it, smell it or taste it — you only feel its effects, and by then exposure has already happened.

  • 0 PPM — normal, fresh air
  • 100 PPM — slight headache after 1–2 hours of exposure
  • 200 PPM — dizziness, nausea, fatigue and headache after 2–3 hours
  • 400 PPM — headache and nausea within 1–2 hours; life-threatening within 3 hours
  • 800 PPM and above — collapse, unconsciousness, and death within hours

With a confirmed CO leak from an obstructed burner, the safe reading is the one you never take a chance on. We closed the gas valve on the spot and instructed the household not to use the heater until it was replaced. The replacement was scheduled for the very next day.

The Replacement: Macro MA-20WODP

The homeowner chose to stay with the same model family — the Macro MA-20WODP, a gas water heater with a preheat function, powered by piped town gas from Citygas (now City Energy). Keeping the same model meant the household got back the exact hot water experience they were used to, on a brand-new, safe unit.

CO leak Gas Water Heater power by Citygas at Skypak - After

What Is the Preheat Function?

A standard gas water heater only starts heating when you open a hot water tap — so the water already sitting in the pipes between the heater and your shower comes out cold first. The longer the pipe run, the longer you wait.

The preheat function solves this with a heating loop return: the heater circulates hot water through the piping in advance, so hot water is already waiting at the outlet the moment you turn on the tap. In practice, this cuts hot water delivery time from around 1 minute to about 5 seconds.

The preheat function delivers the most benefit in homes with long piping runs — double-storey homes, landed properties and penthouses — where the wait for hot water is longest. For this SkyPark Residences household, it was the comfort feature they already knew and did not want to give up: hot water at every outlet within seconds, every morning.

Our Installation Scope

Before starting work, we walked the customer through exactly what a proper gas water heater replacement involves. A safe installation is never just “swap the box on the wall”. Our scope covered:

  • Pre-work checks on the existing gas and water connections
  • Gas valve change-out
  • Gas pipe union removal and gas pipe replacement
  • Water pipe stop valve and water pipe replacement
  • Equipotential bonding
  • Final pressure test on the gas line
  • All works carried out by a Licensed Gas Service Worker, Licensed Plumber and Licensed Electrical Worker
  • Certificate of Gas Safety issued on completion
  • Gas work, plumbing work, electrical work and heater product warranties

The Certificate of Gas Safety is the document that confirms the gas installation has been tested and certified safe by a licensed gas service worker — we have covered what it is and why it matters in detail elsewhere on our website.

CO leak Gas Water Heater power by Citygas at Skypak Final Pressure Test

Testing and Handover

Once installation was complete, we ran a temperature test to confirm the heater was delivering hot water correctly and functioning as intended. We finished with full housekeeping of the work area — the customer’s home was left the way we found it, minus one dangerous heater.

Total time on site: approximately 3.5 to 4 hours.

Conclusion

If your gas water heater is approaching 10 years of age, do not wait for it to fail — and never ignore inconsistent performance. An ageing heater is not just an inconvenience; as this SkyPark Residences case shows, a corroded burner can leak carbon monoxide into your home without any visible warning.

Homeone provides site assessments, CO leak testing, and licensed gas water heater replacement across Sembawang and island-wide, with a Certificate of Gas Safety issued on every gas installation.

 