Aircon Installation in HDB Rental Flats, Mitsubishi System 3 at 56 Lengkok Bahru HDB on 25 Oct 2024

Aircon Installation in HDB Rental Flats-00

Aircon Installation in HDB Rental Flats Condensing Unit (CU) Model: MXY-3H28VG Fan Coil Unit (FCU) Model: MSXY-FP20VG and MSXY-FP10VG Outdoor Unit Technical Specifications: Model: MXY-3H28VG   Indoor Unit Technical Specifications: Model: MSXY-FP20VG Model: MSXY-FP10VG   Aircon Installation in HDB Rental Flats Job Scopes: 1. Site Inspection and Planning Our team conducts a thorough on-site inspection…Read More→

Mitsubishi Cassette Type Aircon Installation for Private Property at Sago St, Chinatown on 7 Oct 2024

Mitsubishi Cassette Aircon Installation for Private Property - Before and After

Mitsubishi Cassette Type Aircon Installation for Private Property Condensing Unit (CU) Model: SUY-M80VA-SG Fan Coil Unit (FCU) Model: PLY-M80EA-SG (Ceiling Mounted Mitsubishi Cassette Type) Mitsubishi SUY-M80VA-SG (Outdoor Unit) Technical Specifications: Model: SUY-M80VA-SG Maximum Current: 16 A (outdoor only) Voltage: 230 V, 50 Hz Weight: 43 kg IP Rating: IP24 Refrigerant: R32, 0.96 kg High-Pressure Rating:…Read More→

Aircon Gas Top-up Mitsubishi: MUY-GE15VA at Sembawang Hills Estate on 3 Sep 2024

Aircon Gas Top-up Mitsubishi - Feature Photo

Aircon Gas Top-up Mitsubishi System 1 Existing Condensing Unit (CU) Model: Mitsubishi MUY-GE15VA   Existing Fan Coil Unit (FCU) Model: Mitsubishi MSY-GE15VA   Reason for the service: The service was needed because the aircon stopped cooling after a handyman’s refrigerant top-up. Despite ruling out a leak through pressure tests, the cooling issue persisted, likely due…Read More→

Aircon Pipe Replacement: Mitsubishi System 3 at Fortune View on 16 Aug 2024

Aircon Pipe Replacement - After installation of exposed aircon pipe and trunking

Aircon Pipe Replacement: Mitsubishi System 3 Existing Aircon CU: Mitsubishi MXY-3G28VA2 Existing Aircon FCU: Mitsubishi MSY-GE13VA This aircon pipe replacement meets the following job scope; 1. Site Assessment and Leak Detection Pressure Gauge Test: Begin with a pressure gauge test to assess the system’s refrigerant levels and identify any significant drops that might indicate a…Read More→

Refrigerant pipe leak repair – Mitsubishi SUY-KA80VA at 273 Bukit Batok East Avenue 4 HDB on 8 Apr 2024

Refrigerant pipe leak repair -Before and After condition of repair-8Apr2024

Refrigerant pipe leak repair for Mitsubishi SUY-KA80VA Condenser Unit Existing Condensing Unit (CU) Model: Mitsubishi SUY-KA80VA   Existing Fan Coil Unit (FCU) Model: Mitsubishi PLY-P80EA Ceiling Cassette Type Reason for the service: Loss of Cooling Capacity- The air conditioner isn’t cooling room space as effectively as it used to Refrigerant pipe leak repair Job Scopes: Preparation…Read More→