A homeowner at People’s Park Centre contacted Homeone after discovering water leakage around their ceiling and discoloured water from their taps. Upon site inspection, our team identified a clear case of “Water Heater Corrosion.” The old Ariston AN 30 R showed signs of tank rust, with leakage forming at the base and pipe joints.
The heater was also installed without several critical safety features. There was no double check valve to prevent backflow into the potable water system, no drainpipe for the pressure relief valve (posing a risk of uncontrolled hot water discharge), and no electrical bonding, which is a direct violation of CP5:1998 safety standards.
Old Water Heater:
Ariston AN 30 R
Old Water Heater:
Ariston AN2 30 RS
To resolve the water heater corrosion and ensure compliance with all regulatory standards, Homeone replaced the old unit with a new Ariston AN2 30 R. This model offers improved build quality, anti-corrosion features, and a compact design ideal for ceiling installations.
We completed the following upgrades:
Installed double check valve to prevent backflow (SS636-compliant)
Connected the drainpipe to the nearest floor trap to manage overflow
Applied electrical bonding to metal components for safety
Replaced inlet and outlet pipework with stainless steel fittings
All work was performed by our team under the supervision of a PUB-licensed plumber and EMA-certified electrician, and the full installation was submitted to PUB for regulatory documentation.
Shut off the water and power supply
Safely removed the corroded Ariston AN 30 R unit
Disconnected non-compliant fittings
Mounted new AN2 30 RS securely
Installed stainless steel inlet/outlet pipework
Fitted double check valve, drainpipe, and stop valve
Applied protective electrical bonding
Recommissioned the system and tested for leaks and safety
Documentation
Conclusion
This water heater corrosion case at People’s Park Centre was a clear reminder of the importance of safe, compliant installation. The replacement of the corroded Ariston AN 30 R with the upgraded AN2 30 R ensures lasting performance, safety, and peace of mind. With proper backflow protection, drainage, and bonding now in place, the homeowner benefits from a fully PUB-compliant hot water system.
Project Location: People’s Park Centre
Read More About Us
Our Water Heater Services